Cisco CX-FEIP-1TX= Installation and con?guration User's Guide Page 240

  • Download
  • Add to my manuals
  • Print
  • Page
    / 648
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 239
Equipment specifications Chapter 4: Reference information
4-8
phn-2513_004v000 (Oct 2012)
RSL
(dBm)
Channel separation
7, 13.75, 14, 27.5, 28,
29.65, 55, 56, 60 or
80 MHz
Bandwidth
10, 20 or
40 MHz
Bandwidth
30 MHz
Bandwidth
50 MHz
-81 0.67 0.76 0.84 0.70
-82 0.61 0.70 0.78 0.64
-83 0.54 0.64 0.72 0.58
-84 0.48 0.57 0.65 0.51
-85 0.42 0.51 0.59 0.45
-86 0.35 0.45 0.53 0.39
-87 0.29 0.38 0.46 0.32
-88 0.23 0.32 0.40 0.26
-89 0.16 0.26 0.34 0.19
-90 0.10 0.19 0.27 0.13
IRFU specifications
The PTP 800 IRFU conforms to the specifications in Table 83, Table 84, Table 85, and
Table 86 and Table 87.
Table 83 IRFU physical specifications
Category Specification
Rack mounting
space (RMS)
Less than 3 RMS (2.77 U) in a NEBS standard 19” rack, for an
IRFU with 2 transceivers and associated BU.
Dimensions (approx) W x D x H (mm): 432 x 280 x 123
W x D x H (in): 17 x 11 x 4.843
Weight 8.1 Kg for 1+0 configuration, including the BU.
11.8 Kg for 1+1 MHSB configuration, including the BU.
Page view 239