PTP 800 Series User Guide Wireless specifications
phn-2513_004v000 (Oct 2012)
4-29
Wireless performance in the 6 GHz band (IRFU)
Applies to IRFU deployments only.
The following tables contain capacity, transmit power and sensitivity data for PTP 800
links operating in the 6 GHz band. For column definitions, refer to Capacity, transmit
power and sensitivity on page 4-22.
The maximum and minimum transmit powers are the powers at the output of an IRFU
transceiver and not at the waveguide interface. The power at the waveguide interface
depends on the branching unit configuration, which adds additional loss according to
Table 116.
The receive sensitivities are at the input to the IRFU transceiver and not at the
waveguide interface. The sensitivity at the waveguide interface depends on the branching
unit configuration, which adds additional loss according to Table 117.
Table 113 6 GHz FCC and Canada with 10 MHz bandwidth for IRFU
Modulation
mode
F/R
mode
Cap
(Mbps)
Sens
(dBm)
ACM-o
(dBm)
ACM-i
(dBm)
Max tx
(dBm)
Min tx
(dBm)
256QAM 0.76 Yes 55.9 -72.7 -64.7 -62.1 29 10
128QAM 0.83 Yes 50.2 -75 -64.5 -61.7 30 10
64QAM 0.78 Yes 40.5 -79.2 -71.2 -69.9 31 10
32QAM 0.79 Yes 31.1 -81.8 -75.5 -74.3 32 10
16QAM 0.88 Yes 27.9 -83.8 -78.4 -77.2 33 10
8PSK 0.88 Yes 21 -85.6 -80.6 -79.4 33 10
QPSK 0.79 Yes 12.6 -90.9 - - 34 10