Page view 242
PTP 800 Series User Guide Equipment specifications
phn-2513_004v000 (Oct 2012)
4-11
The numbered call-outs in Figure 67 are:
1. Antenna flange
2. Tapered transition flanges
3. Flexible waveguide flanges
4. RMK flange
Flanges for each frequency variant
Table 88 specifies the antenna, transition, waveguide and RMK flanges for each frequency
variant.
Table 88 Antenna, transition, waveguide and RMK flanges
Frequency
1
Antenna
flange
2
Tapered
transition
flanges
3
Waveguide
flange
(antenna)
3
Waveguide
flange
(ODU)
4
RMK
flange
Wave
guide
size
6 GHz (*) PDR70 n/a UDR70 PDR70 UDR70 WR137
6 GHz (*) CPR137G n/a CPR137G PDR70 UDR70 WR137
7 GHz PDR84 n/a UDR84 PBR84 UBR84 WR112
8 GHz PDR84 n/a UDR84 PBR84 UBR84 WR112
11 GHz PDR100 UDR100/
PBR120
UBR120 PBR120 UBR120 WR75
13 GHz PBR120 n/a UBR120 PBR120 UBR120 WR75
15 GHz PBR140 n/a UBR140 PBR140 UBR140 WR62
18 GHz PBR220 n/a UBR220 PBR220 UBR220 WR42
23 GHz PBR220 n/a UBR220 PBR220 UBR220 WR42
26 GHz PBR220 n/a UBR220 PBR220 UBR220 WR42
32 GHz PBR320 n/a UBR320 PBR320 UBR320 WR28
38 GHz PBR320 n/a UBR320 PBR320 UBR320 WR28
(*) These flanges are used for both Lower 6 GHz and Upper 6 GHz.