PTP 800 Series User Guide Task 7: Configuring wireless interface
phn-2513_004v000 (Oct 2012)
6-69
Attribute Meaning
Short Power Cycle For
Recovery
‘Enabled means that a short power cycle will cause the CMU
to boot in recovery mode. This is the better option when the
CMU is installed in a location that is difficult to access.
‘Disabled’ means that the CMU will boot in recovery mode
only through use of the front panel recovery switch. This is the
better option when it is reasonably easy to access the CMU to
press the Recovery button.
For more information, see Using recovery mode on page 7-71.
Step 2: Enter details of the radio license
Step 2 of the Installation Wizard is for updating radio license attributes (Figure 144 or
Figure 145 or Figure 146). The attributes are described in Table 233. Update the
attributes as required and select Next.
Figure 144 Step 2: Radio License Configuration page (fixed modulation)