3-18
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 3 Provisioning ATM Services
Quickstart Provisioning Procedures
Cisco BPX PNNI Trunk Configuration Quickstart
When the Cisco SES PNNI controller is attached to a Cisco BPX switch, the Cisco BPX switch can
participate in a PNNI network with Cisco MGX 8850 (PXM45) and Cisco MGX 8950 switches. The
connection between a Cisco MGX 8850 (PXM45) and Cisco MGX 8950 and a Cisco BPX switch is a
trunk between an AXSM card in the Cisco MGX switch and a Cisco BXM card in the Cisco BPX switch.
For instructions on configuring the BXM end of the trunk, refer to the Cisco SES product documentation.
This section describes how to configure the AXSM end of the trunk.
The procedure for configuring the AXSM end of the trunk is similar to the general procedure for
configuring AXSM trunks. The following procedure is customized for setting up Cisco BPX PNNI
trunks.
Note The trunk configuration is not complete until the BXM end of the trunk is configured.
Caution Before you can configure a BPX PNNI trunk, you must allocate PNNI resources. To verify that a PNNI
resource is allocated on the trunk, enter the dsprsrc <slot.port> command on the active PXM.
Note After you configure a Cisco BPX PNNI trunk, the trunk is ready to support SVCs. You can also create
SPVCs and SPVPs between CPE at each end of the trunk as described in the ““Configuring SPVCs and
SPVPs” section on page 3-54,.
Step 10
Refer to the Cisco MGX 8850
PXM1-based documentation.
At the Cisco MGX 8850 PXM1-based feeder, enter the addcon
command to add a connection on the link to the Cisco MGX 8850
(PXM45) switch.
Step 11
Configure the port on the remote routing switch that terminates calls in
the core network. If the remote routing switch port connects to a feeder,
repeat Steps 2 and 3 to configure the remote feeder trunk. If the remote
routing switch port connects to CPE, configure the port for UNI
communications.
Step 12
cc Change to the PXM card.
Step 13
cnfoamsegep Define the local routing switch feeder port as a non-OAM segment
endpoint. This is required to enable testing with the tstdelay command.
Step 14
cc Change back to the AXSM card.
Step 15
addcon
Related commands:
dspcons
Create an SPVC from the local routing switch feeder port to the remote
routing switch termination port.
See the “Configuring SPVCs and SPVPs” section on page 3-54.
Command Comments