5-141
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 5
cnflnalm
cnflnalm
Configure Line Alarm—AXSM-XG
Use the cnflnalm command to configure statistical line alarms thresholds. You can use this command to
make the lines more or less sensitive to alarms.
Syntax (Sonet Section)
cnflnalm -sonetsec <bay.line> -secsev <Severity> -seces15 <ES15min> -seces24 <ES24Hr>
-secses15 <SES15min> -secses24 <SES24Hr> -secsefs15 <SEFS15min> -secsefs24 <SEFS24Hr>
-seccv15 <UAS15min> -seccv24 <UAS24Hr>
Syntax Description (Sonet Sections)
-sonetsec
<bay.line>
Identifies the line on which you want to configure statistical line
alarms thresholds.
Enter the keyword (-sonetsec) followed by the line number, in the
format bay.line. For example: -sonetsec 1.2
Note Use the dsplns command to see the line numbers for all
lines on the current card.
-secsev
<Severity>
Determines the severity of SONET or SDH section statistical
alarm counters. When a Statistical Counter exceeds its specified
threshold, the system sends an alarm with appropriate severity.
Enter a number to indicate the severity for all statistical alarms on
the specified line as follows:
• 1—minor
• 2—major
3—none (no alarm will be raised).
-seces15
<ES15min>
Sets the threshold for errored seconds in the current 15-minute
interval.
-seces24
<ES24Hr>
Sets the threshold for errored seconds in the current 24-hour
interval.
-secses15
<SES15min>
Sets the threshold for severely errored seconds in the current
15-minute interval.
-secses24
<SES24Hr>
Sets the threshold for severely errored seconds in the current
24-hour interval.
-secsefs15
<SEFS15min>
Sets the threshold for severely errored framing seconds in the
current 15-minute interval.
-secsefs24
<SEFS24Hr>
Sets the threshold for severely errored framing seconds in the
current 24-hour interval.
-seccv15
<UAS15min
Sets the threshold for code violations in the current 15-minute
interval.
-seccv24
<CV24Hr>
Sets the threshold for code violations in the current 24-hour
interval.
Comments to this Manuals