5-135
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 5 AXSM Command Reference
cnfimalnktst
cnfimalnktst
Configure IMA Link Test—AXSM-32-T1E1-E
Allows you to change the link number or the test pattern number during an active IMA link connectivity
test on the specified IMA group. You check that an IMA link connection is valid by sending a test pattern
to the link. The test pattern is a number in the range of -1–255. If the test pattern number is the same
when it arrives at the receive endpoint of the link, then the link is valid. If the test pattern number is
different or does not arrive at all, then the link is invalid.
Syntax
cnfimalnktst -grp <group> -lnk <link> -pat <testPat>
Syntax Description
Related Commands
startimalnktest, stopimalnktest
Attributes
Example
Change the link to 3 and the test pattern to 2 on IMA group 1.1:
MGX8850.2.AXSME.a> cnfimalnktst 1.1 3 2
-grp The bay number (1–2) and the IMA group number (1–16) in the format bay.group.
For example: 1.16
-link The bay number (1–2) and the IMA link number (1–16) in the format bay.link. For
example: 1.16
-pat The test pattern number. Range: -1–255.
• -1 causes the program to choose its own pattern.
• 255 causes the link test to stop.
Log: yes State: active Privilege: GROUP1