5-249
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 5
dspcon
dspcon
Display Connection—AXSM, AXSM-E, AXSM-32-T1E1-E, AXSM-XG
Display information about an SPVC. The contents of the display on the AXSM and the PXM45 differ
slightly. On both cards, the dspcon output appears in sections to make the information easier to sort.
Most of the information in the dspcon output comes from addcon execution. See the addcon description
for more information. Also, executing cnfpnni-intf can affect the dspcon output.
Display Connection on the AXSM
On the AXSM, dspcon shows the following connection identifiers:
• NSAP address, logical port, VPI/VCI, status, and ownership of local and remote ends of the
connection. The display shows whether a particular endpoint is the master or slave.
The provisioning parameters in the display show:
• Connection type of VPC or VCC.
• Service type (for example, ABR).
• A number indicating the controller. For example, 2 refers to PNNI. The addcontroller command
specifies the controller.
• The administrative state is either up or down. This state results from addcon or dncon/upcon. Note
that, after you down a connection with at the connection master endpoint, the dspcon command
shows the connection as “down” when you execute it at the master endpoint and “failed” when you
execute it at the slave endpoint. (See also dncon description).
• The operational state is either OK or failed. The operational state can apply to a connection
regardless of the administrative state.
The traffic management parameters consist of:
• Local and remote UPC parameters of PCR, MBS, CTD, CDVT, and so on. A –1 in a field means that
the parameter was not specified. The characters “N/A” indicate that the parameter does not apply to
the service type.
These other fields also pertain to connection integrity:
• OAM connectivity check enable or disable.
• Loopback test enable/disable and loopback type.
• Round trip delay in microseconds. This field is non-zero only if you previously executed tstdelay.
The dspcon command requires a unique connection identifier. If you do not have the information to
identify a connection, execute dspcons. On the AXSM, dspcons identifies all the connections on the
AXSM. On the PXM45, dspcons identifies all the connections on the node. (See dspcons description).
Display Connection on the AXSM-E, AXSM-32-T1E1-E, AXSM-XG
The display output on the AXSM-E and AXSM-XG also displays RDI (Remote Defect Indication)
information at the ATM Layer through the OAM mechanism in Ingress and Egress directions.
Syntax
dspcon <ifNum> <vpi> <vci>
Comments to this Manuals