3-43
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 3 Provisioning ATM Services
General AXSM Configuration Procedures
ctrlr_id A number that identifies a network controller. The range for reserved controller IDs is
1–3 and is the same for all AXSM models. The reserved controller IDs are as follows:
1 = PAR (Portable AutoRoute)—currently not used
2 = PNNI
3 = LSC (Label Switch Controller, also known as MPLS for Multiprotocol Label Switch
Controller)
The absolute ranges for the AXSM and AXSM-E are as follows:
• AXSM: 1–60
• AXSM-E: 1–32
egrminbw A guaranteed percentage of egress bandwidth. Each unit of egrminbw is 0.000001 of the
total bandwidth on the port. (An egrMinBw of 1000000 = 100%.) This approach provides
a high level of granularity.
egrmaxbw A maximum percentage of the bandwidth. Each unit of egrmaxbw is 0.000001 of the total
bandwidth available to the port. (An egrMaxBw of 1000000 = 100%.) The resulting
bandwidth must be at least 50 cps.
ingminbw A guaranteed percentage of the ingress bandwidth. Each unit of ingminbw is 0.000001
of the total bandwidth available to a port. For example, an ingMinBw of 1000000 =
100%.
ingmaxbw A maximum percentage of the ingress bandwidth. Each increment of ingmaxbw is
0.000001 of the total bandwidth on the port. For example, an ingMaxBw of
1000000 = 100%. Note that the maximum ingress bandwidth must be at least 50 cps.
min_vpi Minimum VPI. For NNI, the range is 0–4095. For UNI, the range is 0–255.
max_vpi Maximum VPI in the range 0–4095 for an NNI. For a UNI, the range is 0–255. The
maxvpi cannot be less than the minvpi.
min_vci Minimum VCI:
AXSM range: 0–2000 (OC-48 only) or 1–65535
max_vci Maximum VCI:
AXSM range: 0–2000 (OC-48 only) or 32–65535
minConns Guaranteed number of connections. The range is between 0 and the maximum number of
connections in the port group. See dspcd for information about port groups.
Note On UNI ports, 1% of the <minConns> value is reserved for signaling.
maxConns A maximum number of connections. The range is between 10 and the maximum number
of connections in the port group. See dspcd port group information. The value of
maxConns cannot be less than the value of minConns.
Table 3-9 addpart Command Parameters (continued)
Parameter Description
Comments to this Manuals