C-52
Cisco Media Gateway Manager 5.0 User Guide
OL-5461-02
Appendix C Troubleshooting
Chassis View Problems
Possible alternative workaround—You can select the lines from the Tree View to launch other
applications.
C.7.3 Card Not Displayed in MGX Nodes
Card is not displayed in the Chassis View in MGX nodes.
Step 1 Check that entries for the card is available in the card table.
Step 2 Check whether the lines are defined in the XML file ChassisView.xml.
Step 3 Make sure that the node is in sync (mode is 3).
Defect Information
If the details are not found in the DB, this probably is an EM issue. If the details are found, then
Step 4 Use cwmver to get the Cisco MGM version.
Step 5 Get the node table information for the node using echo "select * from node where node_id=<NodeId> "
| dbaccess " and save it in a file.
Step 6 Get the card table information for the card using echo "select * from card where node_id=<NodeId> and
slot=<Slot>" | dbaccess and save it in a file.
Step 7 Save the log from the client machine from the location "D:\Documents and
Settings\<login-name>\log\CMSCclient.log".
Step 8 Take a copy of the "chassisview.jar" from the location "/opt/svplus/java/jars/cwm/". We need to check
that gif files used to draw the lines are available in the jar.
Possible alternative workaround—You can select the cards from the Tree View to launch other
applications.
C.7.4 DCA/DCB Status Not Displayed in PXM Cards
DCA/DCB status is always greyed in Chassis View. DCA/DCB status information is not received from
the switch. So the status is not displayed or updated.
C.7.5 Ethernet Status Not Updated in PXM Cards
Ethernet status is received only when the Chassis View is launched. Dynamic changes in states of the
ethernet status is not updated in Chassis View.
C.7.6 HIST, CBRX, CBTX Status Not Updated in MGX Nodes
For MGX nodes, only CPUOK LED status is updated in Chassis View. Chassis View is not managing
the LEDs for HIST, CBRX, CBTX.