Cisco PXM Version 1.1 User's Guide Page 698

  • Download
  • Add to my manuals
  • Print
  • Page
    / 972
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 697
C-84
Cisco Media Gateway Manager 5.0 User Guide
OL-5461-02
Appendix C Troubleshooting
Connection Management Problems
C.9.4.2.6 Cmgrd—Sdbroker Modification/Deletion Errors. Modifying or Deleting a Connection Results in an Error "sDatabroker
Could not lock connection entry.".
Related key index entries: cmgrd, sdbroker, lock connection
During a Connection Modification or Deletion request the above error could result when sdbroker could
not find the connection in its cache.
All scenarios of modify/delete connection failures display the same error to the user. To determine
exactly what happened you must view the /opt/svplus/log/sdbrokerX.XXXX.log file.
Step 1 Search for the ERR: "<sDbkr_CmgrdModConn_c::Process> INTERFACE ERROR" near the end of the
file. A detailed reason for the error will follow on the same line.
a. Note that for delete connections, search for sDbkr_CmgrdDelConn_c::Process instead of
sDbkr_CmgrdModConn_c::Process.
Defect Information:
If the problem is an intermediate endpoint and it is on the switch but EM didn't process it or didn't'
send the message to DMD see section EM logs,nts logs from /opt/svplus/log.
If the problem is within the DMD we ill need the dmd logs, dmd message logs and the dmd cache
dump.
Possible alternative workaround—None
C.9.4.3 Cmgrd Errors
During an Addition request cmgrd could return errors which cmgrd has received from snmpcomm or the
switch itself.
This section includes the following information:
C.9.4.3.1 Cmgrd—Addition/Modification/Deletion Errors. Provisioning a Connection Results in
an Error "Fail due to Switch Timeout"
C.9.4.3.2 Cmgrd—Addition/Modification/Deletion Errors. Provisioning a Connection Results in
an Error “Agent not responding, request timed-out; or Fatal error, SnmpComm is not running.”
C.9.4.3.3 Cmgrd—Addition/Modification/Deletion Errors. Provisioning a Connection Results in
an Error "Outstanding request exists for same object."
C.9.4.3.4 Cmgrd—Addition/Modification/Deletion Errors. Provisioning a Connection Results in
an Error "Fatal error, IOSMGR is not running, may need to be manually started"
C.9.4.3.5 Cmgrd—Addition Errors. Provisioning a Connection Results in an Error "Vpi/vci ranges
retrieval from svc_operation failed"
C.9.4.3.6 Cmgrd—Addition/Modification/Deletion Errors. Provisioning a Connection Results in
an Error "Can't get segment info from Data-base."
Page view 697
1 ... 697 698 699 ... 972

Comments to this Manuals

No comments