C-100
Cisco Media Gateway Manager 5.0 User Guide
OL-5461-02
Appendix C Troubleshooting
Diagnostics Center Problems
Defect Information—Collect the following information for further analysis:
• Collect CMSClient.log file under the D:\Documents and Settings\username\log directory.
• Collect DCServer.log file under the /opt/svplus/log directory.
Possible alternative workaround—None
C.10.2.3 Node Syncup Status Are Not Shown in the Diagnostic Center GUI
When Diagnostic Center is launched for a network element, the GUI does not show the Node syncup
status for all the nodes in the network.
Step 1 Run "selnd" as svplus and check the status of all the nodes. If they are not shown properly then there
should be some problem with the EM process. Check the EM logs.
Step 2 Check the node table entries for all the nodes.
Defect Information—Collect the following information for further analysis:
• node table entry for the corresponding node.
• DCServer.log file from the log directory.
Possible alternative workaround—None
C.10.2.4 Node Resync Fails
Node resync fails from Diagnostic Center.
Step 1 Check whether the node is reachable.
Step 2 Check for any exceptions in the DCServer.log file.
Defect Information—Collect the following information for further analysis:
• node table entry for the corresponding node.
• DCServer.log file from the log directory.
• emd.log from the log directory.
Possible alternative workaround—None
C.10.2.5 Polling of Real Time Counters Fails
Unable to poll Realtime counters from DC GUI
Step 1 Check whether the node is reachable and the community strings are set correctly.
Step 2 Check whether those objects are applicable. Check any appropriate commands from CLI.
Step 3 Use any snmp tool and check whether the mib objects are retrievable.
Comments to this Manuals