Cisco ONS 15454 SDH Specifications Page 111

  • Download
  • Add to my manuals
  • Print
  • Page
    / 262
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 110
2-31
Cisco ONS 15454 SDH Troubleshooting and Maintenance Guide, R3.3
May 2002
Chapter 2 General Troubleshooting
Fiber and Cabling
2.4.5 Free-Running Synchronization Mode
Symptom The clock is running at a different frequency than normal and the FRNGSYNC alarm appears.
Table 2-20 describes the potential cause(s) of the symptom and the solution(s).
2.4.6 Daisy-Chained SETS Not Functioning
Symptom You are unable to daisy-chain the SETS.
Table 2-21 outlines the problem that might cause this symptom and describes solutions to the problem.
2.5 Fiber and Cabling
This section explains problems typically caused by cabling connectivity errors. It also includes
instructions for crimping Cat 5 cable and lists the optical fiber connectivity levels.
2.5.1 Bit Errors Appear for a Traffic Card
Symptom A traffic card has multiple Bit errors.
Table 2-22 describes the potential cause(s) of the symptom and the solution(s).
Table 2-20 Free-Running Synchronization Mode
Possible Problem Solution
No reliable reference
input is available.
The clock is using the internal oscillator as its only frequency reference. This
occurs when no reliable, prior timing reference is available. See the
“FRNGSYNC” section on page 1-34 for a detailed description of this alarm.
Table 2-21 Daisy-Chained SETS Not Functioning
Possible Problem Solution
Daisy-chaining SETS is
not supported on the
ONS 15454 SDH.
Daisy-chaining SETS causes additional wander buildup in the network and
is therefore not supported. Instead, use a timing signal generator to create
multiple copies of the SETS clock and separately link them to each
ONS 15454 SDH.
Page view 110
1 ... 110 111 112 ... 262

Comments to this Manuals

No comments