Cisco ONS 15454 SDH Specifications Page 141

  • Download
  • Add to my manuals
  • Print
  • Page
    / 262
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 140
3-21
Cisco ONS 15454 SDH Troubleshooting and Maintenance Guide, R3.3
May 2002
Chapter 3 Card Reference
E3-12 Card
3.9.2 E3-12 Port-Level Indicators
You can find the status of the twelve E3-12 card ports using the LCD screen on the ONS 15454 SDH fan
tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number
and severity of alarms for a given port or slot. Refer to Chapter 1, “Alarm Troubleshooting, for a
complete description of the alarm messages.
Figure 3-12 E3-12 block diagram
3.9.3 E3-12 Specifications
E3-12 Input
Bit Rate: 34.368 MBits/s (Mbps) + 20 ppm
Line Code: HDB-3
Termination: Unbalanced coaxial cable
Input Impedance: 75 + 5%
Cable Loss: up to 12 dB at 17184 kHz (for cable length see specification of the cable that you
are using)
AIS: ITU-T G.704-compliant
E3-12 Output
Table 3-9 E3-12 Card-Level Indicators
Card-Level LEDs Description
Red FAIL LED The red FAIL LED indicates the card’s processor is not ready. This LED is
lit during Reset. The FAIL LED flashes during the boot process. Replace the
card if the FAIL LED persists.
ACT/STBY LED
Green (Active)
Yellow (Standby)
When the ACTV/STBY LED is green, the E3-12 card is operational and
ready to carry traffic. When the ACTV/STBY LED is yellow, the E3-12 card
is operational and in standby (protect) mode.
Yellow SF LED The yellow SF LED indicates a signal failure or condition such as port LOS.
BTC
ASIC
E3
ASIC
63120
Protection
Relay
Matrix
B
a
c
k
p
l
a
n
e
12
Line
Interface
Units
Page view 140
1 2 ... 136 137 138 139 140 141 142 143 144 145 146 ... 261 262