![](/jointfilesconvert/417580/bg97.png)
3-31
Cisco ONS 15454 SDH Troubleshooting and Maintenance Guide, R3.3
May 2002
Chapter 3 Card Reference
FMEC-E3/DS3 Card
–
Line Code: HDB-3
–
Termination: Unbalanced coaxial cable
–
Output Impedance: 75 Ω + 5%
–
Pulse Shape: ITU-T G.703 Figure 17
–
Pulse Amplitude: ITU-T G.703 Figure 17 and Table 9
• FMEC-E3/DS3 Input (for DS3 signals)
–
Bit Rate: 44.736 MBits/s (Mbps) + 20 ppm
–
Line Code: B3ZS
–
Termination: Unbalanced coaxial cable
–
Input Impedance: 75 Ω + 5%
–
Cable Loss: Max 137 m (450 ft) 734A, RG59, 728A / Max 24 m (79 ft) RG179
• FMEC-E3/DS3 Output (for DS3 signals)
–
Bit Rate: 44.736 MBits/s (Mbps) + 20 ppm
–
Line Code: B3ZS
–
Termination: Unbalanced coaxial cable
–
Output Impedance: 75 Ω + 5%
–
AIS: TR-TSY-000191-compliant
–
Power Level: ITU-T G.703, Table 6; -1.8 - +5.7 dBm
–
Pulse Shape: ITU-T G.703, Table 6 and Figure 14; ANSI T1.102-1988 Figure 8
–
Pulse Amplitude: ITU-T G.703, Table 6; 0.36 - 0.85 V peak-to-peak
–
Line Build Out: 0-225 ft; 226-450 ft
• FMEC-E3/DS3 Electrical Interface
–
Connectors: 1.0/2.3 Miniature Coax connectors
• Environmental
–
Operating Temperature: -5 to +45 degrees Celsius
–
Operating Humidity: 5 to 95%, non-condensing
–
Power Consumption: 0.00 W, 0.00 A (AMPS) at -48V, 0.0 BTU/hr
• Dimensions
–
Height: 182 mm (7.165 in.)
–
Width: 32 mm (1.25 in.)
–
Depth: 92 mm (3.62 in.)
–
Depth with backplane connector: 98 mm (3.87 in.)
–
Weight not including clam shell: 0.3 kg (0.7 lb)
• Compliance
ONS 15454 SDH cards, when installed in a system, comply with these standards:
–
Safety: IEC 60950, EN 60950, UL 60950, CSA C22.2 No. 60950, TS 001, AS/NZS 3260