Cisco ONS 15454 SDH Specifications Page 179

  • Download
  • Add to my manuals
  • Print
  • Page
    / 262
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 178
3-59
Cisco ONS 15454 SDH Troubleshooting and Maintenance Guide, R3.3
May 2002
Chapter 3 Card Reference
OC48 ELR/STM16 EH 100 GHz Cards
Environmental
Eye Safety Compliance: Class 1 (EN60825)
Operating Temperature: -5 to +45 degrees Celsius
Operating Humidity: 5 to 95%, non-condensing
Power Consumption: 37.20 W, 0.78 A (AMPS) at -48V, 127.0 BTU/hr
Dimensions
Height: 321.3 mm (12.650 in.)
Width: 18.2 mm (0.716 in.)
Depth: 228.6 mm (9.000 in.)
Depth with backplane connector: 235 mm (9.250 in.)
Weight not including clam shell: 0.9 kg (2.2 lb)
Compliance
ONS15454 SDH optical cards, when installed in a system, comply with these standards:
Safety: IEC 60950, EN 60950, UL 60950, CSA C22.2 No. 60950, TS 001, AS/NZS 3260, IEC
60825-1, IEC 60825-2, 21 CFR 1040-10 and 21 CFR 1040.11.
Class 1 laser product
3.24 OC48 ELR/STM16 EH 100 GHz Cards
Eighteen distinct STM-16 ITU 100 GHz dense wavelength division multiplexing (DWDM) cards
comprise the ONS 15454 SDH DWDM channel plan. This plan contains every second in a series of 100
GHz spacing wavelengths. Though the ONS 15454 SDH only uses 200 GHz spacing, the cards work in
100 GHz spacing nodes, as well. Each OC48 ELR/STM16 EH 100 GHz card provides one ITU-T G.692,
ITU-T G.707, ITU-T G.957, ITU-T G.958-compliant, SDH STM-16 port. The interface operates at
2.488 GBits/s (Gbps) over a single-mode fiber span. Each card supports concatenated or
non-concatenated payloads at STM-1, STM-4, or STM-16 signal levels on a per VC-4 basis. Figure 3-39
shows the OC48 ELR/STM16 EH 100 GHz faceplate and Figure 3-40 shows a block diagram of the card.
Warning
Class 1 laser product.
Page view 178
1 2 ... 174 175 176 177 178 179 180 181 182 183 184 ... 261 262

Comments to this Manuals