Cisco ONS 15454 SDH Troubleshooting and Maintenance Guide, R3.3
May 2002
Chapter 1 Alarm Troubleshooting
Alarm Procedures
Step 2 If two nodes have the same node ID number, change one node ID number so that each node has a unique
node ID:
a. Display the network view.
b. Log into one of the nodes that uses the repeated node ID recorded in Step 1.
Note If the node names shown on the network view do not correlate with the node IDs, log into
each node and click the Provisioning > Ring tabs. This screen displays the node ID of the
node you are logged into.
c. Click the node ID table cell to reveal a pull-down menu.
d. Select a unique node ID from the pull-down menu and click Apply.
Note Locking out and clearing the lockout on a span causes the ONS 15454 SDH to generate a
new K byte. The APSCNMIS alarm clears when the node receives a K byte containing the
correct node ID.
Step 3 If the alarm does not clear, lockout a span on the ring and then clear the lockout:
a. Click the Maintenance > Ring tabs.
b. Click the table cell under the West Switch heading to reveal the pull-down menu.
c. Select LOCKOUT SPAN and click Apply.
d. Click OK in the MS-SPRing operation dialog box.
e. Click the same table cell under the West Switch heading to reveal the pull-down menu.
f. Select CLEAR and click Apply.
g. Click OK on the MS-SPRing operations dialog box.
1.5.7 AU-LOP
Critical, Service-affecting
An administration unit loss of pointer (LOP) alarm applies to optical cards. It is raised when the first
payload pointer is not synchronized according to the system clock.
Warning
The ONS 15454 SDH is a Class I (CDRH) and Class 1M (IEC) laser system.
Warning
Invisible laser radiation may be emitted from the aperture ports of the single-mode fiber optic
modules when no cable is connected. Avoid exposure and do not stare into open apertures.
Procedure: Clear the AU-LOP Alarm
Step 1 Check for LOS on the reporting card.