Cisco ONS 15454 SDH Specifications Page 188

  • Download
  • Add to my manuals
  • Print
  • Page
    / 262
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 187
3-68
Cisco ONS 15454 SDH Troubleshooting and Maintenance Guide, R3.3
May 2002
Chapter 3 Card Reference
E100T-G Card
Maximum Receiver Level: -9 dBm at BER 1 * 10
-12
(see remark)
Minimum Receiver Level: -17 dBm at BER 1 * 10
-12
(see remark)
Receiver: APD/TIA
Link Loss Budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at BER = 1 *
10
-12
including dispersion
Environmental
Operating Temperature: -5 to +45 degrees Celsius
Operating Humidity: 5 to 95%, non-condensing
Power Consumption: 72.20 W, 1.50 A (AMPS) at -48V, 246.5 BTU/hr
Dimensions
Height: 321.3 mm (12.650 in.)
Width: 18.2 mm (0.716 in.)
Depth: 228.6 mm (9.000 in.)
Depth with backplane connector: 235 mm (9.250 in.)
Weight not including clam shell: 1.3 kg (3.1 lb)
Compliance
ONS15454 SDH optical cards, when installed in a system, comply with these standards:
Safety: IEC 60950, EN 60950, UL 60950, CSA C22.2 No. 60950, TS 001, AS/NZS 3260, IEC
60825-1, IEC 60825-2, 21 CFR 1040-10 and 21 CFR 1040.11.
Class 1M (IEC 60825-1 2001.01) and class I (21 CFR 1040.10 and 1040.11) laser product
Note The optical output power of the OC192 LR/STM64 LH 1550 (+7 dBm to +10 dBm) is 3 dB lower
than in L-64.2b of the pre published unedited version 10/2000 of ITU-T G.691 (+10 dBm to +13
dBm). However, the total attenuation range of the optical path, 22 to 16 dB, is maintained by the
optical receiver sensitivity range of the OC192 LR/STM64 LH 1550 (-9 dBm to -17 dBm). This
sensitivity range outperforms the specification in L-64.2b of the pre published unedited version
10/2000 of ITU-T G.691 (-14 dBm to -3 dBm).
3.26 E100T-G Card
The E100T-G card provides twelve ports of IEEE 802.3-compliant, 10/100 interfaces. Each interface
supports full-duplex operation for a maximum bandwidth of 200 MBits/s (Mbps) per port and 2.488
GBits/s (Gbps) per card. Each port independently detects the speed of an attached device (auto-senses)
and automatically connects at the appropriate speed. The ports auto-configure to operate at either half
or full duplex and can determine whether to enable or disable flow control. Figure 3-43 shows the card
faceplate and Figure 3-44 shows a block diagram of the card.
Page view 187
1 2 ... 183 184 185 186 187 188 189 190 191 192 193 ... 261 262

Comments to this Manuals

No comments