Cisco ONS 15454 SDH Troubleshooting and Maintenance Guide, R3.3
May 2002
Chapter 1 Alarm Troubleshooting
Alarm Procedures
Step 3 If only one card slot reporting the alarm, perform a software reset of the traffic card:
a. Display the CTC node view.
b. Position the cursor over the slot reporting the alarm.
c. Right-click and choose RESET CARD.
Step 4 If the software reset does not clear the alarm, physically reseat the reporting card.
Step 5 If all traffic cards report this alarm, perform a software reset of the active TCC-I card:
a. Display the CTC node view.
b. Position the cursor over the active TCC-I card slot.
c. Right-click and choose RESET CARD.
Step 6 If the software reset does not clear the alarm, physically reseat the TCC-I card.
Step 7 If the alarm still does not clear, replace the TCC-I card.
Note When replacing a card with an identical type of card, you do not need to change the CTC
database.
1.5.16 CONTBUS-A-18
Major, Non-service affecting
The communication failure from TCC-I slot to TCC-I slot alarm means the main processor on the TCC-I
card in Slot 7 has lost communication with the coprocessor on the second TCC-I card in Slot 11. The
problem is with the physical path of communication from the TCC-I card to the reporting card. The
physical path of communication includes the two TCC-I cards and the backplane.
Caution Always use the supplied electrostatic discharge wristband when working with a powered
ONS 15454 SDH. Plug the wristband cable into the ESD jack located on the middle-right outside edge
of the shelf assembly.
Procedure: Clear the CONTBUS-A-18 Alarm
Step 1 Position the cursor over the TCC-I card in Slot 7.
Step 2 Right-click the mouse to reveal a menu.
Step 3 To clear the alarm, choose RESET CARD to make the standby TCC-I in Slot 11 the active TCC-I and
clear the alarm.
Step 4 Wait approximately two minutes for the TCC-I in Slot 7 to reset as the standby TCC-I.
Step 5 Position the cursor over the TCC-I card in Slot 11.
Step 6 Right-click the mouse to reveal a menu.
Step 7 Choose RESET CARD to make the standby TCC-I in Slot 7 the active TCC-I.