5-26
Device Manager Guide, Cisco ACE 4700 Series Application Control Engine Appliance
OL-26645-02
Chapter 5 Configuring Virtual Servers
Configuring Virtual Servers
e. Do the following:
–
Click OK to save your entries. The Conditions table refreshes with the new entry.
–
Click Cancel to exit the Policy subset without saving your entries.
f. In the Default Action field, select the default action that the virtual server is to take when specified
match conditions for protocol inspection are not met:
–
Permit—Indicates that the specified HTTP traffic is to be received by the virtual server.
–
Reset—Indicates that the specified HTTP traffic is to be denied by the virtual server.
–
N/A—Indicates that this attribute is not set.
URL URL names are to be used for application inspection decisions.
In the URL field, enter a URL or a portion of a URL to match. Valid entries are URL strings from
1 to 255 alphanumeric characters and include only the portion of the URL following
www.hostname.domain. For example, in the URL www.anydomain.com/latest/whatsnew.html,
include only /latest/whatsnew.html.
URL Length URL length is to be used for application inspection decisions.
1. In the URL Length Operator field, select the operand to use to compare URL length:
–
Equal To—The URL length must equal the number in the URL Length Value field.
–
Greater Than—The URL length must be greater than the number in the URL Length Value
field.
–
Less Than—The URL length must be less than the number in the URL Length Value field.
–
Range—The URL length must be within the range specified in the URL Length Lower
Value field and the URL Length Higher Value field.
2. Enter values to apply for URL length comparison:
–
If you select Equal To, Greater Than, or Less Than in the URL Length Operator field, the
URL Length Value field appears. In the URL Length Value field, enter the value for
comparison. Valid entries are from 1 to 65535 bytes.
–
If you select Range in the URL Length Operator field, the URL Length Lower Value and
the URL Length Higher Value fields appear:
1. In the URL Length Lower Value field, enter the lowest number of bytes to be used for
this match condition. Valid entries are integers from 1 to 65535. The number in this field
must be less than the number entered in the URL Length Higher Value field.
2. In the URL Length Higher Value field, enter the highest number of bytes to be used for
this match condition. Valid entries are integers from 1 to 65535. The number in this field
must be greater than the number entered in the URL Length Lower Value field.
Table 5-6 HTTP and HTTPS Protocol Inspection Conditions and Options (continued)
Condition Description
Comments to this Manuals