4-17
Cisco Intrusion Prevention System Appliance Hardware Installation Guide for IPS 7.1
OL-24002-01
Chapter 4 Installing the IPS 4345 and IPS 4360
Removing and Installing the Power Supply
Figure 4-11 shows both the removable AC (on the left) and DC (on the right) power supplies for the
IPS 4360.
Figure 4-11 AC Power Supply and DC Power Supply
Table 4-4 describes the power supply indicator. The function of the indicator is the same for both the AC
and DC power supplies.
1 Power supply indicator 2 DC power supply positive connection
3 DC power supply neutral connection 4 DC power supply negative connection
11 2 3 4
333056
Table 4-4 AC and DC Power Supply Indicator
Indicator Color and State Description
Solid green Power output is on and within the normal operating range.
Blinking green, at the rate of one
blink per second
Input power that is within the normal operating range is being
supplied, but the Standby switch is in the Standby position (and
not in the On position).
Solid amber A power supply critical event has occurred, and the power
supply has shut down. The critical event can be temperature,
voltage, current, or fan operating outside the normal operating
range.