5-34
Cisco Intrusion Prevention System Appliance Hardware Installation Guide for IPS 7.1
OL-24002-01
Chapter 5 Installing the IPS 4510 and IPS 4520
Troubleshooting Loose Connections
Figure 5-18 Cable Management Brackets for the Slide Rail
Step 4 Tighten the screws in to the rack.
Step 5 Reattach the power cable to the sensor.
Step 6 Organize the cables through the cable management brackets on the sensor.
Step 7 Power on the sensor.
Troubleshooting Loose Connections
Perform the following actions to troubleshoot loose connections on sensors:
• Make sure all power cords are securely connected.
• Make sure all cables are properly aligned and securely connected for all external and internal
components.
• Remove and check all data and power cables for damage. Make sure no cables have bent pins or
damaged connectors.
• Make sure each device is properly seated.
• If a device has latches, make sure they are completely closed and locked.
• Check any interlock or interconnect indicators that indicate a component is not connected properly.
• If problems continue, remove and reinstall each device, checking the connectors and sockets for bent
pins or other damage.
Comments to this Manuals