Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 5 SNMP MIB Configuration
5.6.4 Case Temperature
5.6.4.2 Case Temperature Alarm Threshold
5.6.4.2.1 CtmpMin
Command Types snmp attribute get local cerent15216EdfaCtmpMin
Syntax Description snmp attribute get local cerent15216EdfaCtmpMin
This command displays minimum case temperature alarm threshold.
5.6.4.2.2 CtmpMax
snmp attribute get local cerent15216EdfaCtmpMax
Syntax Description snmp attribute get local cerent15216EdfaCtmpMax
This command displays maximum case temperature alarm threshold.
The following command displays case temperature alarm threshold and other temperature data:
• snmp row display local cerent15216EdfaCfgGroup command
This command is shown in Example 5-14.
Example 5-14 cerent15216EdfaCfgGroup Display Command
ash:
hostname
:ONS15216 EDFA2> snmp row display local cerent15216EdfaCfgGroup
CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaCfgGroup ::=
{
cerent15216EdfaCfgSaved = true;
cerent15216EdfaLpoutSetpoint = 0;
cerent15216EdfaLpoutDeviation = 200;
cerent15216EdfaLpoutHysteresis = 100;
cerent15216EdfaLOSThreshold = -3102;
cerent15216EdfaLOSHysteresis = 100;
cerent15216EdfaCtmpMin = -5;
cerent15216EdfaCtmpMinHysteresis = 1;
cerent15216EdfaCtmpMax = 65;
cerent15216EdfaCtmpMaxHysteresis = 1;
cerent15216EdfaCLEI = "WMM4180BRA";
cerent15216EdfaPowerBusMode = duplex;
cerent15216EdfaPowerBusDCVoltageMin = 420;
cerent15216EdfaPowerBusDCVoltageMax = 700;
};
Refer to Table 5-20 on page 5-23 for information about all of the parameters in
cerent15216EdfaOverallStatusGroup.