Chapter 9 TL1 Commands
9.6.33 RTRV-DWDM
Table 9-39 RTRV-DWDM Syntax Description
Parameter Syntax Description
date yyyy-mm-dd Date of origination of TL1 message.
time hh:mm:ss Time of origination of TL1 message.
aid 1 and ALL have same input effect.
1 Directly affecting the optical signal.
ALL Any or all of the preceding (command input only).
inputpoweruw 0 - 99999 Input power (signal) in units of 10 microW
(cerent15216EdfaInPoweruW).
inputpowerdbm –999999 -
999999
Input power (signal) in units of 100 dBm
(cerent15216EdfaInPowerdBm).
outputpowermw 0 - 999999 Output power in units of 100 mW
(cerent15216EdfaOutPowermW).
outputpowerdbm –99999 - 99999 Output power in units of 100 dBm
(cerent15216EdfaOutPowerdBm).
pump1ctrlmode,
pump2ctrlmode
Pump 1 or pump 2 configured control mode (maps to
cerent15216EdfaPumpCfgControlMode for the corresponding
pump). Possible values are:
GAINTEMP Constant Gain Temperature Compensated mode (manufacturer
default) (cerent15216EdfaPumpCfgControlMode set to
constGainTempComp).
OPWR Constant Output Power mode
(cerent15216EdfaPumpCfgControlMode set to
constOutputPower). A valid mode only for pump 2.
CRNT Constant Pump Current mode
(cerent15216EdfaPumpCfgControlMode set to constCurrent).
PWR Constant Pump Power mode
(cerent15216EdfaPumpCfgControlMode set to constPower).
IDLE Pump is shut down (cerent15216EdfaPumpCfgControlMode
set to idle).
pump1ctrlvalue,
pump2ctrlvalue
Pump 1 or pump 2 configured control value. This value’s
interpretation depends on the control mode of the
corresponding pump. Possible values are:
0 - 650 Output power in units of 10 mW when mode is OPWR (gets
cerent15216EdfaPumpCfgConstOutPower).
0 - 300 Current value in mA when mode is CRNT (gets
cerent15216EdfaPumpCfgConstPumpCurrent).
0 - 100 Pump power in mW when mode is PWR (gets
cerent15216EdfaPumpCfgConstPumpPower).
pump1ctrlmodem
easured,
pump2ctrlmodem
easured
Pump 1 or pump 2 measured control mode. Possible values are
same as pump1ctrlmode and pump2ctrlmode, as shown above.