Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.10 ED-DWDM
Example 9-12 ED-DWDM Command
Amp01:ONS15216 EDFA2>
ED-DWDM:Amp01:ALL:123:::PUMP1CTRLMODE=GAINTEMP;
Table 9-16 ED-DWDM Syntax Description
Parameter Syntax Description
aid 1 and ALL have same input effect.
1
Directly affecting the optical signal.
ALL
Any or all of the preceding (command input only).
pump1ctrlmode,
pump2ctrlmode
Pump 1 or pump 2 control mode (maps to
cerent15216EdfaPumpCfgControlMode for the corresponding
pump). Generally, pump1ctrlmode and pump2ctrlmode must be
the same value. One exception is OPWR which is not valid for
pump 1 and can only be set for pump 2. Possible values are:
GAINTEMP Constant Gain Temperature Compensated mode (manufacturer
default) (cerent15216EdfaPumpCfgControlMode set to
constGainTempComp). Setting one pump sets the other pump
to the same mode.
OPWR Constant Output Power mode
(cerent15216EdfaPumpCfgControlMode set to
constOutputPower). This is not a valid mode for pump 1. If
pump 2 is set to OPWR, pump 1 gets automatically set to PWR.
CRNT Constant Pump Current mode
(cerent15216EdfaPumpCfgControlMode set to constCurrent).
Setting one pump sets the other pump to the same mode.
PWR Constant Pump Power mode
(cerent15216EdfaPumpCfgControlMode set to constPower).
Setting one pump sets the other pump to the same mode.
IDLE Pump is shut down (cerent15216EdfaPumpCfgControlMode
set to idle). Setting one pump sets the other pump to the same
mode.
pump1ctrlvalue,
pump2ctrlvalue
Pump 1 or pump 2 control value. This value’s interpretation
depends on the control mode of the corresponding pump.
Possible values are:
0 - 650 Output power in units of 10 mW when mode is OPWR (sets
cerent15216EdfaPumpCfgConstOutPower). The default value
is 0.
0 - 300 Current value in mA when mode is CRNT (sets
cerent15216EdfaPumpCfgConstPumpCurrent). The default
value is 0. Must set pump 1 and pump 2 at the same time.
0 - 100 Pump power in mW when mode is PWR (sets
cerent15216EdfaPumpCfgConstPumpPower). The default
value is 0.
overallgain 130 - 220 Value of gain in units of 10 dB when mode is GAINTEMP (sets
cerent15216EdfaConstGainOverallGain).