9-73
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.47 SET-TH-EQPT
Table 9-53 SET-TH-EQPT Syntax Description
Parameter Syntax Description
aid Possible values are:
EQPT General parameters of the ONS 15216 EDFA2.
PWR-A Sets Power Bus A and Power Bus B.
PWR-B Sets Power Bus A and Power Bus B.
ALL Any or all of the preceding (command input only).
threshholdtype
and
thresholdvalue
pairs
string Type of threshold that is to be set. The threshold is set to the
thresholdvalue that follows the comma. Possible to specify
values for one or more of the following:
MAXCTMP Maximum case temperature (cerent15216EdfaCtmpMax).
thresholdvalue can be between 20 and 70, with default of 70
in units of
°C.
MAXCTMPHYST Maximum case temperature hysteresis
(cerent15216EdfaCtmpMaxHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in
units of
°C.
MINCTMP Minimum case temperature (cerent15216EdfaCtmpMin).
thresholdvalue can be between –10 and 10, with default of
–5, in units of
°C.
MINCTMPHYST Minimum case temperature hysteresis
(cerent15216EdfaCtmpMinHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in
units of
°C.
PWRBUSMIN Power bus minimum voltage
(cerent15216EdfaPowerBusDCVoltageMin).
thresholdvalue can be between 350 and 700, with default of
420, in units of –10 VDC.
The power bus threshold has a 1.0V tolerance and a 1.0V
hysteresis. If the minimum threshold is configured at 400
(-40 VDC), the alarm may raise anywhere between -42 to
-40.5V and will not clear until the voltage goes above
-41VDC.
PWRBUSMAX Power bus maximum voltage
(cerent15216EdfaPowerBusDCVoltageMax).
thresholdvalue can be between 350 and 700, with default of
570, in units of –10 VDC.
The power bus threshold has a 1.0V tolerance and a 1.0V
hysteresis. If the maximum threshold is configured at 570
(-57 VDC), the alarm may raise anywhere between -57 to
-58.5V and will not clear until the voltage goes below -56
VDC.