9-54
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.31 RTRV-COND-EQPT
Example 9-35 RTRV-COND-EQPT Command and Response
Amp01:ONS15216 EDFA2>
RTRV-COND-EQPT:Amp01:ALL:229::LCRNT1;
Amp01 2002-06-20 14:30:00
M 229 COMPLD
"EQPT:MN,LCRNT1,NSA,6-20,14-25-30,,,\"Excessive Pump1 Current\""
;
Table 9-37 RTRV-COND-EQPT Syntax Description
Parameter Syntax Description
aid EQPT and ALL have same input effect.
EQPT General parameters of the ONS 15216 EDFA2.
PWR-A Affecting Power Bus A.
PWR-B Affecting Power Bus B.
ALL Any or all of the preceding (command input only).
conddescr Detailed text description of the event. The conddescr is 1 to
64 characters of ASCII text. See condtype below.
condtype Condition type identifies the type of alarm (maps to
cerent15216EdfaLogEventID). Possible condtype and
corresponding conddescr (in quotes) are:
CTMP “Case Temperature Out of Range” alarm
(cerent15216EdfaAlarmCtmp).
DBBACKUP “Database Backup In Progress” alarm
(cerent15216EdfaOpDbBackup).
DBRESTORE “Database Restore In Progress” alarm
(cerent15216EdfaOpDbRestore).
LCRNT1 “Excessive Pump1 Current” alarm
(cerent15216EdfaAlarmLcrnt1).
LCRNT2 “Excessive Pump2 Current” alarm
(cerent15216EdfaAlarmLcrnt2).
LTMP1 “Excessive Pump1 Temperature” alarm
(cerent15216EdfaAlarmLtmp1).
LTMP2 “Excessive Pump2 Temperature” alarm
(cerent15216EdfaAlarmLtmp2).
PWRBUSA “Power Bus A (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusA).
PWRBUSB “Power Bus B (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusB).
SFTWDOWN “Software Download In Progress” alarm
(cerent15216EdfaOpLoad).
date yyyy-mm-dd Date of origination of TL1 message.
Comments to this Manuals