5-39
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 5 SNMP MIB Configuration
5.6.6 Input Power (Signal)
5.6.6.1.2 InPowerdBm
Command Types snmp attribute get local cerent15216EdfaInPowerdBm
Syntax Description snmp attribute get local cerent15216EdfaInPowerdBm
Displays the input power value in dBm. The dBm units are converted from µW to dBm, so theses values
could be slightly different due to rounding error.
The following command displays input power value and other status information:
• snmp row display local cerent15216EdfaOverallStatusGroup command
For information about all of the parameters in the cerent15216EdfaOverallStatusGroup table, refer to
Table 5-20 on page 5-23.
5.6.6.2 Loss of Signal (Input Power) Alarm Threshold
Command Types snmp attribute get local cerent15216EdfaLOSThreshold
Syntax Description snmp attribute get local cerent15216EdfaLOSThreshold
Displays the loss of signal (input power) alarm threshold.
The following command displays the loss of input power alarm threshold and other laser power and
temperature data:
• snmp row display local cerent15216EdfaCfgGroup command
The cerent15216EdfaLOSThreshold attribute in the cerent15216EdfaCfgGroup display command shows
the loss of input power alarm threshold (Example 5-14 on page 5-36).
For information about all of the parameters in the cerent15216EdfaCfgGroup table, refer to Table 5-13
on page 5-16.
5.6.6.3 Loss of Signal (Input Power) Alarm Hysteresis
Command Types snmp attribute get local cerent15216EdfaLOSHysteresis
Syntax Description snmp attribute get local cerent15216EdfaLOSHysteresis
Displays the loss of signal (input power) alarm hysteresis value.
The following command displays the loss of input power hysteresis value and other laser power and
temperature data:
• snmp row display local cerent15216EdfaCfgGroup command
Comments to this Manuals