5-16
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 5 SNMP MIB Configuration
5.4.6 CfgGroup
Table 5-13 cerent15216EdfaCfgGroup Variable Descriptions
Variable Syntax
Maximum
Access Description
cerent15216Edfa
CfgSaved
Truth Value
(true default)
Read-only Indicates whether the current configuration has
been saved. The object
cerent15216EdfaOpSaveConfig can be used to
save the current configuration.
cerent15216Edfa
LpoutSetpoint
Integer
(0 to 1000,
0 default)
Read-only Laser pump output power setpoint for the Lpout
alarm, in units of 0.1 mW. This is set automatically
when the pump mode for pump 2 is set to
cerent15216EdfaPumpCfgConstPumpPower or
cerent15216EdfaPumpCfgConstOutPower.
cerent15216Edfa
LpoutDeviation
Integer
(0 to 1000,
200 default)
Read-write Amount by which the output power must deviate
from the setpoint to set the Lpout alarm, in units of
0.01 dB. For example, a value of 200 is actually
2.00 dB.
cerent15216Edfa
LpoutHysteresis
Integer
(0 to 1000,
100 default)
Read-write Amount the output power must move towards the
setpoint before the Lpout alarm is cleared, in units
of 0.01 dB. For example, a value of 100 is actually
1.00 dB.
cerent15216Edfa
LOSThreshold
Integer
(–3100 to –1500,
–3000 default)
Read-write Loss of signal threshold, in units of 0.01 dBm. For
example, a value of -3000 is actually -30.0 dBm.
cerent15216Edfa
LOSHysteresis
Integer
(0 to 1000,
100 default)
Read-write Amount above cerent15216EdfaLOSThreshold
the input signal must rise before the Lpin alarm is
cleared, in units of 0.01 dB. For example, a value
of 100 is actually 1.0 dB.
cerent15216Edfa
CtmpMin
Integer
(–10 to 10,
–5 default)
Read-write Minimum allowable case temperature in degrees
Celsius.
cerent15216Edfa
CtmpMinHystere
sis
Integer
(0 to 10,
1 default)
Read-write Amount above cerent15216EdfaCtmpMin that the
case temperature must rise before the Ctmp alarm
is cleared, in degrees Celsius.
cerent15216Edfa
CtmpMax
Integer
(20 to 70,
70 default))
Read-write Maximum allowable case temperature in degrees
Celsius.
cerent15216Edfa
CtmpMaxHyster
esis
Integer
(0 to 10,
1 default)
Read-write Amount below cerent15216EdfaCtmpMax that the
case temperature must drop before the Ctmp alarm
is cleared, in degrees Celsius.
cerent15216Edfa
CLEI
Display String
(0 to 10
characters)
Read-only Indicates the factory setting of the Common
Language Equipment Identifier (CLEI) code
(established by Telcordia) of the Cisco ONS
15216 EDFA2. This attribute can be accessed but
not changed by the user.
cerent15216Edfa
PowerBusMode
simplex(1),
duplex(2)
Read-write Simplex for one power source (Bus A) or duplex
for redundant power source (Bus A and Bus B)
Power Bus mode.