9-51
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.29 RTRV-COND-ALL
condtype
(ccm)
Condition type identifies the type of alarm (maps to
cerent15216EdfaLogEventID). Possible condtype and
corresponding conddescr (in quotes) are:
LOS
(DWDM)
“Loss of Signal” (input power) alarm
(cerent15216EdfaAlarmLpin).
GAIN
(DWDM)
“Gain Out of Range” alarm (cerent15216EdfaAlarmGain).
LPOUT
(DWDM)
“Loss of Output Power” alarm (cerent15216EdfaAlarmLpout).
CTMP
(EQPT)
“Case Temperature Out of Range” alarm
(cerent15216EdfaAlarmCtmp).
DBBACKUP
(EQPT)
“Database Backup In Progress”
(cerent15216EdfaOpDbBackup).
DBRESTORE
(EQPT)
“Database Restore In Progress”
(cerent15216EdfaOpDbRestore).
LCRNT1
(EQPT)
“Excessive Pump1 Current” alarm
(cerent15216EdfaAlarmLcrnt1).
LCRNT2
(EQPT)
“Excessive Pump2 Current” alarm
(cerent15216EdfaAlarmLcrnt2).
LTMP1
(EQPT)
“Excessive Pump1 Temperature” alarm
(cerent15216EdfaAlarmLtmp1).
LTMP2
(EQPT)
“Excessive Pump2 Temperature” alarm
(cerent15216EdfaAlarmLtmp2).
PWRBUSA
(EQPT)
“Power Bus A (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusA).
PWRBUSB
(EQPT)
“Power Bus B (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusB).
SFTWDOWN
(EQPT)
“Software Download In Progress” (cerent15216EdfaOpLoad).
date yyyy-mm-dd Date of origination of TL1 message.
ntfncde Notification code (maps to cerent15216EdfaAlarmPriority).
Possible values are:
CR Critical alarm.
MJ Major alarm.
MN Minor alarm.
NA Not alarmed.
NR Not reported.
ocrdat m-d Date (month-day) of the event occurrence (derived from
cerent15216EdfaDateAndTimeString).
ocrtm h-m-s Time (hour-minute-second) of the event occurrence (derived
from cerent15216EdfaDateAndTimeString).
Table 9-35 RTRV-COND-ALL Syntax Description (continued)
Parameter Syntax Description