3-15
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 3 Installation
3.4.5 LAN Interface (Ethernet)
• ASH CLI commands (Chapter 6, “ASH Commands”)
• TL1 commands (Chapter 9, “TL1 Commands”)
3.4.5.1 LAN Connection Procedure
Use the following procedure to configure the module to accept SNMP, CLI, and TL1 commands via its
RJ-45 LAN port:
Step 1 The ONS 15216 EDFA2 IP address is factory set at 0.0.0.0. The IP address must be set before the ONS
15216 EDFA2 can be accessed via the Ethernet port. See the “4.2 Set IP Address” section on page 4-3.
Step 2 Connect ONS 15216 EDFA2 to the network via the module LAN port.
Use a straight-through Cat5 Ethernet cable with RJ-45 connectors to connect to a LAN, or use a
cross-over cable if connecting directly to a PC.
Step 3 At a terminal or workstation, open the Telnet application.
Note To send CLI and TL1 commands over IP, a Telnet client is required. For SNMP management over
IP, a generic SNMP manager is required.
Step 4 Connect to the ONS 15216 EDFA2 using the module’s IP address.
If you do not specify a port number, the ONS 15216 EDFA2 responds in the shell that the ONS 15216
EDFA2 is set to (TL1 is the default shell). Specify port number 8023 to access through the ASH shell or
port number 3083 to access through the TL1 shell.
The ONS 15216 EDFA2 login screen appears. See the “4.1 Log In via RS-232 (EIA/TIA-232) Port
Using HyperTerminal” section on page 4-1 for the login procedure in ASH shell and the “8.1 Log In via
RS-232 (EIA/TIA-232) Port Using HyperTerminal” section on page 8-1 for the login procedure in TL1
shell.