9-12
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.2 ALW-MSG-ALL
condtype Condition type of the alarm or event that is to be allowed.
(Maps to cerent15216EdfaLogEventID.) ALL maps to
all types. A null maps to none of the types, i.e., with a
null, all existing condtype inhibitions are kept
unchanged. Possible condtype and corresponding
conddescr (in quotes) are:
LOS “Loss of Signal” (input power) alarm
(cerent15216EdfaAlarmLpin).
GAIN “Gain Out of Range” alarm
(cerent15216EdfaAlarmGain).
LPOUT “Loss of Output Power” alarm
(cerent15216EdfaAlarmLpout).
CTMP “Case Temperature Out of Range” alarm
(cerent15216EdfaAlarmCtmp).
DBBACKUP “Database Backup In Progress” alarm
(cerent15216EdfaOpDbBackup).
DBRESTORE “Database Restore In Progress” alarm
(cerent15216EdfaOpDbRestore).
LCRNT1 “Excessive Pump1 Current” alarm
(cerent15216EdfaAlarmLcrnt1).
LCRNT2 “Excessive Pump2 Current” alarm
(cerent15216EdfaAlarmLcrnt2).
LTMP1 “Excessive Pump1 Temperature” alarm
(cerent15216EdfaAlarmLtmp1).
LTMP2 “Excessive Pump2 Temperature” alarm
(cerent15216EdfaAlarmLtmp2).
POWERBUSA “Power Bus A (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusA).
POWERBUSB “Power Bus B (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusB).
SFTWDOWN “Software Download In Progress” alarm
(cerent15216EdfaOpLoad).
Table 9-9 ALW-MSG-ALL Syntax Description (continued)
Parameter Syntax Description