5-46
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 5 SNMP MIB Configuration
5.7 Summary of SNMP Alarms and Events
Table 5-29 summarizes the ONS 15216 EDFA2 SNMP event traps.
7 gain Gain out of range. Gain has deviated more than 1.25
dB from the setpoint in constGainTempComp mode.
This alarm is also triggered if the input power goes
outside the manufacturer-defined range by more than
0.15 dB.
Major
8 ctmp The case temperature out of the threshold range. Minor
9 powerBusA The Power Bus A voltage is out of the threshold range.
The power bus threshold has a 1.5V tolerance and a
1.0V hysteresis. There is a ±1.5V inaccuracy in the
ONS 15216 EDFA2 voltage measurement.
Minor/Critical
1
10 powerBusB The Power Bus B voltage is out of the threshold range.
The power bus threshold has a 1.5V tolerance and a
1.0V hysteresis. There is a ±1.5V inaccuracy in the
ONS 15216 EDFA2 voltage measurement.
Minor/Critical
1
11 dbBackup A database backup is in progress. Minor
12 dbRestore A database restore is in progress. Minor
13 swDownload A TFTP software download is in progress. Minor
1. If the power system is in simplex mode, a power bus alarm is Critical by default. If the power system is in duplex mode, a
single power bus alarm is Minor by default, and if an alarm is raised on both power buses, the second alarm is Critical.
Table 5-28 SNMP Alarms (continued)
Alarm Index Alarm ID Description Default Priority
Table 5-29 SNMP Events
Notification Notification Trigger Default Priority Condition
cerent15216Edfa
OpStarted
and
cerent15216Edfa
OpFinished
cerent15216EdfaOpSaveConfig
cerent15216EdfaOpCutover
cerent15216EdfaOpLoad
cerent15216EdfaOpReset
cerent15216EdfaOpDbBackup
cerent15216EdfaOpDbRestore
NSA
NSA
NSA
NSA
NSA
NSA
Notification is generated
when an operation from the
affected attributes list starts
and when it completes or
terminates.