Chapter 5 SNMP MIB Configuration
5.4.15 PumpStatusEntry
b. Set the mode.
Example 5-7 shows how to set the value for Constant Pump Current mode to be 200 mA and then set the
mode to Constant Pump Current mode again for the settings to take effect.
Example 5-7 Changing Value for Constant Pump Current Mode
ash:
hostname
:ONS15216 EDFA2> snmp attribute set local
cerent15216EdfaPumpCfgConstPumpCurrent 1 200
ash:
hostname
:ONS15216 EDFA2> snmp attribute set local
cerent15216EdfaPumpCfgConstPumpCurrent 2 200
ash:
hostname
:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgControlMode 1
constCurrent
5.4.15 PumpStatusEntry
The cerent15216EdfaPumpStatusEntry table is used to display optical amplification module data.
Table 5-22 displays information regarding the cerent15216EdfaPumpStatusEntry table variables.
Table 5-22 cerent15216EdfaPumpStatusEntry Variable Descriptions
Variable Syntax
Maximum
Access Description
cerent15216EdfaPumpStatus
PumpNum
Integer (1 or 2) Not
Accessible
Laser pump number
cerent15216EdfaPumpStatus
LaserChipTemp
Integer
(–9999 to 9999)
Read-only Laser chip temperature in units of
0.1
°C. For example, a value of 260 is
actually 26.0
°C.
cerent15216EdfaPumpStatus
LaserChipTempSetpoint
Integer
(0 to 999)
Read-only Laser chip temperature setpoint in
units of 0.1
°C. For example, a value of
260 is actually 26.0
°C.
cerent15216EdfaPumpStatus
LaserTECCurrent
Integer
(0 to 99999)
Read-only Laser TEC current (mA).
cerent15216EdfaPumpStatus
LaserPower
Integer
(0 to 99999)
Read-only Laser power in units of 0.01 mW. For
example, a value of 3230 is actually
32.30 mW.
cerent15216EdfaPumpStatus
LaserCurrent
Integer
(0 to 999999)
Read-only Laser current in units of 0.01 mA. For
example, a value of 4024 is actually
40.24 mA.
cerent15216EdfaPumpStatus
AmbientTemp
Integer
(–9999 to 9999)
Read-only Ambient temperature in units of
0.01
°C. For example, a value of 2454
is actually 24.54
°C.
cerent15216EdfaPumpStatus
DCVoltage
Integer
(0 to 9999)
Read-only Pump DC voltage in units of 0.1V. For
example, a value of 52 is actually 5.2V.
cerent15216EdfaPumpStatus
InPoweruW
Integer
(0 to 99999)
Read-only Optical input power to the pump, in
units of 0.1 microW. For example, a
value of 1764 is actually 176.4
microW.