Cisco 15216 EDFA2 Specifications Page 88

  • Download
  • Add to my manuals
  • Print
  • Page
    / 252
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 87
5-22
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 5 SNMP MIB Configuration
5.4.11 OpGroup
cerent15216Edfa
OpCutover
idle(1),
perform(2),
abort(3)
Read-write When “perform” is written to this object, a cutover
occurs where the cerent15216EdfaAlternateVersion
software image will be loaded after a Management
Module reset.
The cutover operation is achieved automatically by
swapping cerent15216EdfaBootEntry 1 & 2, then
performing a Management Module reset. That is, the
pre-reset cerent15216EdfaAlternateVersion
becomes the post-reset
cerent15216EdfaCurrentVersion and vice-versa.
cerent15216Edfa
OpLoad
idle(1),
perform(2),
abort(3)
Read-write When “perform” is written to this object, a new
software image is downloaded via TFTP. Before
setting this attribute, the source of the new software
image should be specified by setting
cerent15216EdfaOpSrcFileName and
cerent15216EdfaOpTftpSrvAddr.
cerent15216Edfa
OpSrcFileName
Display String
(0 to 127
characters)
Read-write Source file name for the Load operation. This must
include the path of the file relative to the TFTP
server’s root directory, e.g. images/image1.
cerent15216Edfa
OpTftpSrvAddr
IpAddress Read-write TFTP file server address for the Load operation.
cerent15216Edfa
OpReset
idle(1),
perform(2),
abort(3)
Read-write When “perform” is written to this object, a software
reset is performed. The reset is delayed by
approximately 10 seconds to allow SNMP response
to be sent to the manager before the reset is
performed.
cerent15216Edfa
OpDbFileName
Display String
(0 to 20
characters)
Read-write Database file name for the Db Backup and Db
Restore operations.
cerent15216Edfa
OpDbBackup
idle(1),
perform(2),
abort(3)
Read-write When “perform” is written to this object, the
amplifier identification data and configuration are
written to the specified Db backup file.
Before setting this attribute, the Db backup file name
must specified by setting
cerent15216EdfaDbFileName.
cerent15216Edfa
OpDbRestore
idle(1),
perform(2),
abort(3)
Read-write When “perform” is written to this object, the
amplifier select configuration is restored from the
specified DB backup file.
Before setting this attribute, the Db backup file name
must specified by setting
cerent15216EdfaDbFileName
Table 5-18 cerent15216EdfaOpGroup Variable Descriptions (continued)
Variable Syntax
Maximum
Access Description
Page view 87
1 ... 87 88 89 ... 252

Comments to this Manuals

No comments