Cisco 15216 EDFA2 Specifications Page 236

  • Download
  • Add to my manuals
  • Print
  • Page
    / 252
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 235
9-72
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.47 SET-TH-EQPT
9.6.47 SET-TH-EQPT
Command Types SET-TH-EQPT
Sets general threshold values for the ONS 15216 EDFA2.
Syntax Description
SET-TH-EQPT:[<tid>]:<aid>:<ctag>::<thresholdtype>,<thresholdvalue>[,,];
Example 9-52 SET-TH-EQPT Command
Amp01:ONS15216 EDFA2>
SET-TH-EQPT:Amp01:ALL:123::MAXCTMP,60;
Table 9-52 SET-TH-DWDM Syntax Description
Parameter Syntax Description
aid 1 and ALL have same input effect.
1 Directly affecting the optical signal.
ALL Any or all of the preceding (command input only).
threshholdtype
and
thresholdvalue
pairs
string Type of threshold that is to be set. The threshold is set to the
thresholdvalue that follows the comma. Possible to specify
values for one or more of the following:
LOSHYST Loss of signal (input power) hysteresis
(cerent15216EdfaLOSHysteresis).
thresholdvalue can be between 0 and 1000, with default of
100, in units of 100 dB.
LOSTH Loss of signal (input power) threshold
(cerent15216EdfaLOSThreshold).
thresholdvalue can be between –3100 and –1500, with
default of –3000, in units of 100 dBm.
LPOUTDEV Loss of output power deviation
(cerent15216EdfaLpoutDeviation).
thresholdvalue can be between 0 and 1000, with default of
200, in units of 100 dB.
LPOUTHYST Loss of output power hysteresis
(cerent15216EdfaLpoutHysteresis).
thresholdvalue can be between 0 and 1000, with default of
100, in units of 100 dB.
Page view 235