Chapter 8 Provisioning with TL1
8.8 Set Alarm Thresholds
Figure 8-1 ONS 15216 EDFA2 Front Panel
Alarms are reported for the following conditions:
• Degradation of electrical power source
• Laser pump overheating or excessive pump current
• Loss or degradation of optical input (signal)
• Loss of output power or gain out of range
• Case temperature out of range
Alarms can be connected to a NOC NMS via a network element miscellaneous discrete input and/or
office alarm panel/system.
For a full description of alarm threshold command attributes, refer to Chapter 9, “TL1 Commands.”
To display the alarm thresholds, use the RTRV-TH-DWDM and RTRV-TH-EQPT commands (see the
“9.6.39 RTRV-TH-DWDM” section on page 9-63 and the “9.6.40 RTRV-TH-EQPT” section on
page 9-64) according to the following syntax:
RTRV-TH-DWDM:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,DWDM:<thresholdtype>,,,<thresholdvalue>"
RTRV-TH-EQPT:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<thresholdtype>,,,<thresholdvalue>"
Example 8-8 shows sample command outputs.
Example 8-8 Displaying the Alarm Thresholds Using TL1
sidtidname
:ONS15216 EDFA2>
RTRV-TH-DWDM::ALL:124;
sidtidname
2002-07-11 11:15:19
M 124 COMPLD
"1,DWDM:LOSTH,,,-3000"
"1,DWDM:LOSHYST,,,5"
"1,DWDM:LPOUTDEV,,,1000"
"1,DWDM:LPOUTHYST,,,5"
"1,DWDM:LPOUTSETPT,,,0"
;
sidtidname
:ONS15216 EDFA2>
RTRV-TH-EQPT::ALL:125;
-48V B
RET B
-48V A
RET A
RS-232
(EIA/TIA-232)
LAN port
LAN LEDs
Fiber
output
monitor
port
Power
level
warning
Alarm
out
Fiber
output
port
Status
LEDs
Fiber
input
port
71176
-48V A
R A
POWER
FAIL
LOS
-48V B
R B
CISCO ONS 15216
RS-232
ALARM OUT
LAN
Comments to this Manuals