9-21
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.11 ED-EQPT
9.6.11 ED-EQPT
Command Types ED-EQPT
Configures the ONS 15216 EDFA2 equipment (power bus) parameters.
Syntax Description
ED-EQPT:[<tid>]:<aid>:<ctag>:::PWRBUSMODE=<pwrbusmode>;
Example 9-13 ED-EQPT Command
Amp01:ONS15216 EDFA2>
ED-EQPT:Amp01:ALL:123:::PWRBUSMODE=SIMPLEX;
9.6.12 ED-NE-GEN
Command Types ED-NE-GEN
preatt 10 - 100 Gain pre-attenuation value in units of 10 dB when mode is other
than GAINTEMP (sets
cerent15216EdfaVariableGainPreAttenuation).
als Automatic Laser Shutdown (sets
cerent15216EdfaALSModeEnable).
ENABLED When input power (signal) goes below the LOSTH value, the
laser pumps are shut down until the input signal is restored
beyond the value of LOSHYST.
DISABLED ASE is present (typically –3.5 dBm) at the output during LOS
state.
Table 9-16 ED-DWDM Syntax Description (continued)
Parameter Syntax Description
Table 9-17 ED-EQPT Syntax Description
Parameter Syntax Description
aid
PWR-A
PWR-B
ALL
PWR-A, PWR-B, and ALL have same input effect.
pwrbusmode Power bus mode. Possible values are:
SIMPLEX Simplex mode. Requires power only to bus A. Sets
cerent15216EdfaPowerBusMode to simplex.
DUPLEX Duplex mode (default). Requires power to both bus A and bus
B. Sets cerent15216EdfaPowerBusMode to duplex.