Cisco 15216 EDFA2 Specifications Page 228

  • Download
  • Add to my manuals
  • Print
  • Page
    / 252
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 227
9-64
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.40 RTRV-TH-EQPT
9.6.40 RTRV-TH-EQPT
Command Types RTRV-TH-EQPT
Retrieves general threshold values for the ONS 15216 EDFA2.
Syntax Description
RTRV-TH-EQPT:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<thresholdtype>,,,<thresholdvalue>"
;
threshholdtype
and
thresholdvalue
pairs
Type of threshold or set point that is to be retrieved. A null
value is equivalent to ALL. Possible to specify values for one
or more of the following:
LOSHYST Loss of signal (input power) hysteresis
(cerent15216EdfaLOSHysteresis).
thresholdvalue can be between 0 and 1000, with default of 100,
in units of 100 dB.
LOSTH Loss of signal (input power) threshold
(cerent15216EdfaLOSThreshold).
thresholdvalue can be between –3100 and –1500, with default
of –3000, in units of 100 dBm.
LPOUTDEV Loss of output power deviation
(cerent15216EdfaLpoutDeviation).
thresholdvalue can be between 0 and 1000, with default of 200,
in units of 100 dB.
LPOUTHYST Loss of output power hysteresis
(cerent15216EdfaLpoutHysteresis).
thresholdvalue can be between 0 and 1000, with default of 100,
in units of 100 dB.
LPOUTSETPT Loss of output power set point
(cerent15216EdfaLpoutSetpoint). This read-only value is only
valid when amplifier is in Constant Output Power (OPWR) and
Constant Pump Power (PWR) modes. Can be disregarded when
in Constant Gain Temperature Compensated (GAINTEMP) or
Constant Pump Current (CRNT) mode.
thresholdvalue is read-only and automatically determined by
the pump control mode with a possible value between 0 and
1000 in units of 10 mW.
Table 9-45 RTRV-TH-DWDM Syntax Description (continued)
Parameter Syntax Description
Page view 227
1 ... 227 228 229 ... 252

Comments to this Manuals

No comments