Cisco 15216 EDFA2 Specifications Page 111

  • Download
  • Add to my manuals
  • Print
  • Page
    / 252
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 110
5-45
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 5 SNMP MIB Configuration
5.7 Summary of SNMP Alarms and Events
CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaAlarmEntry ::=
{
cerent15216EdfaAlarmIndex = 2;
cerent15216EdfaAlarmID = lcrnt2;
cerent15216EdfaAlarmPriority = minor;
cerent15216EdfaAlarmState = cleared;
cerent15216EdfaAlarmEnable = enabled;
cerent15216EdfaAlarmDateAndTime = "2002-10-16,13:31:55.4 -8:60";
cerent15216EdfaAlarmCfgPriority = minor;
};
CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaAlarmEntry ::=
{
cerent15216EdfaAlarmIndex = 3;
cerent15216EdfaAlarmID = ltmp1;
...
For information about all of the parameters in the cerent15216EdfaAlarmEntry table, refer to Table 5-10
on page 5-14.
5.7 Summary of SNMP Alarms and Events
Alarm priorities can be configured (cerent15216EdfaAlarmCfgPriority), so the default values are
provided in the tables below. Table 5-28 summarizes the ONS 15216 EDFA2 SNMP alarms.
Table 5-28 SNMP Alarms
Alarm Index Alarm ID Description Default Priority
1 lcrnt1 Excessive pump current for pump 1. Drive current
greater than 95% of end of life value. Current must
drop to 90% of end of life value for alarm to clear.
Minor
2 lcrnt2 Excessive pump current for pump 2. Drive current
greater than 95% of end of life value. Current must
drop to 90% of end of life value for alarm to clear.
Minor
3 ltmp1 Pump 1 laser temperature out of range. Chip
temperature deviating more than 10 degrees C from the
manufacturer-defined setpoint.
Minor
4 ltmp2 Pump 2 laser temp. out of range. Chip temperature
deviating more than 10 degrees C from the
manufacturer-defined setpoint.
Minor
5 lpout Loss of output power. EDFA output power is deviating
more than the value of
cerent15216EdfaLpoutDeviation from the value of
cerent15216EdfaLpoutSetpoint. This alarm is only
valid for constOutputPower mode.
Major
6 lpin Loss of input power (signal). EDFA input power is
below the value of cerent15216EdfaLOSThreshold.
Major
Page view 110