Chapter 9 TL1 Commands
9.6.34 RTRV-EQPT
9.6.34 RTRV-EQPT
Command Types RTRV-EQPT
Retrieves the ONS 15216 EDFA2 equipment parameter configuration.
Syntax Description
RTRV-EQPT:[<tid>]:<aid>:<ctag>;
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:PWRBUSMODE=<pwrbusmode>"
,
Example 9-38 RTRV-EQPT Command and Response
Amp01:ONS15216 EDFA2>
RTRV-EQPT:Amp01:ALL:123;
Amp01 2002-06-20 14:30:00
M 123 COMPLD
"PWR-B:PWRBUSMODE=DUPLEX"
;
pump1ctrlvaluem
easured,
pump2ctrlvaluem
easured
Pump 1 or pump 2 measured control value. Possible values are
same as pump1ctrlvalue and pump2ctrlvalue, as shown above.
gainmeasured 0 - 230 Value of gain in units of 10 dB when mode is GAINTEMP (gets
cerent15216EdfaConstGainOverallGainMeasured).
gain 130 - 220 Value of configured gain setpoint in units of 10 dB when mode
is GAINTEMP (gets
cerent15216EdfaConstGainOverallGainMeasured). Same as
OVERALLGAIN.
preattmeasured 0 - 110 Gain pre-attenuation value in units of 10 dB (gets
cerent15216EdfaVariableGainPreAttenuationMeasured).
als Automatic Laser Shutdown (sets
cerent15216EdfaALSModeEnable).
ENABLED When input power (signal) goes below the LOSTH value, the
laser pumps are shut down until the input signal is restored
beyond the value of LOSHYST.
DISABLED ASE is present (typically –3.5 dBm) at the output during LOS
state.
Table 9-39 RTRV-DWDM Syntax Description (continued)
Parameter Syntax Description