2-428
Cisco SCE 8000 CLI Command Reference
Chapter 2 CLI Command Reference
show interface linecard attack-detector
show interface linecard attack-detector
Displays the configuration of the specified attack detector.
show interface linecard slot-number attack-detector [default | all]
show interface linecard slot-number attack-detector attack-detector
Syntax Description
Command Default None
Command Modes User EXEC
Command History This table includes the following release-specific history entries:
Usage Guidelines When you specify the all or default keyword, the following information is displayed:
• Protocol side—Whether the attack detector applies to attacks originating at the subscriber or
network side.
• Direction—Whether the attack detector applies to single-sided or dual-sided attacks.
• Action to take if an attack is detected.
• Thresholds:
–
open-flows-rate—Default threshold for the rate of open flows (new open flows per second).
–
suspected-flows-rate—Default threshold for the rate of suspected DDoS flows (new suspected
flows per second).
–
suspected-flows-ratio—Default threshold for the ratio of suspected flow rate to open flow rate.
• Subscriber notification—Enabled or disabled.
• Alarm—Sending an SNMP trap is enabled or disabled.
Authorization: viewer
slot-number Number of the identified slot. Enter a value of 0.
default Displays the default attack detector configuration.
all Displays the configuration of all existing attack detectors.
attack-detector Number of the specific attack detector to be displayed.
Release Modification
2.5.7 This command was introduced.