3-3
Cisco ONS 15454 SDH Installation and Operations Guide, R3.3
May 2002
Chapter 3 Node Setup
Setting Up Basic Node Information
Figure 3-1 Setting up general node information
Step 3 Enter the following:
Node NameType a name for the node. For TL1 compliance, names must begin with an alpha
character and have no more than 20 alphanumeric characters. (TL1 is not available in SDH Software
R3.3.)
ContactType the name of the node contact person and the phone number (optional).
LocationType the node location, for example, a city name or specific office location (optional).
LatitudeEnter the node latitude: N (North) or S (South), degrees, and minutes (optional).
LongitudeEnter the node longitude: E (East) or W (West), degrees, and minutes (optional).
CTC uses the latitude and longitude to position node icons on the network view map.
Note You can also position nodes manually by pressing Ctrl and dragging the node icon to a new location.
To convert a coordinate in degrees to degrees and minutes, multiply the number after the decimal by
60. For example, the latitude 38.250739 converts to 38 degrees, 15 minutes (.250739 x 60 = 15.0443,
rounded to the nearest whole number).
Use SNTP/NTP ServerWhen checked, CTC uses a Simple Network Time Protocol (SNTP) server
or Network Time Protocol (NTP) server to set the date and time of the node. Using an SNTP/NTP
server ensures that all ONS 15454 SDH network nodes use the same date and time reference. The
server synchronizes the nodes time after power outages or software upgrades.
If you check Use SNTP/NTP Server, type the servers IP address in the next field. If you do not use
an SNTP/NTP server, complete the Date, Time, and Time Zone fields. The ONS 15454 SDH will use
these fields for alarm dates and times. (CTC displays all alarms in the login nodes time zone for
cross network consistency.)
DateType the current date if you did not select Use SNTP/NTP Server.