Provisioning Electrical Cards
7.2.1 E1-N-14 Card Parameters
The ONS 15454 SDH E-1 cards (E1-N-14) provide fourteen E-1 ports. Each port operates at 2.048
MBits/s (Mbps). Default thresholds are based on recommendations in ITU-T G.841.
Procedure: Modify Line and Threshold Settings for the E-1 Card
Step 1 Display the E1-N-14 in CTC card view.
Step 2 Click the Provisioning tab (Figure 7-4).
Step 3 Depending on the setting you need to modify, click the Line, Line Thrshld, Elect Path Thrshld, SDH
Thrshld, or Alarming tabs.
Step 4 Modify the settings shown in Table 7-3. For drop-down lists, choose an item from the list. For numerics,
double-click the field and type the new number.
Step 5 Click Apply.
Step 6 Repeat Steps 4 5 for each subtab that has parameters you want to provision.
Alarming
Port XXX
Profile X X X
Suppress Alarms X X X
Purpose Set the E1 (2048 kBits/s) interface parameters for required connection
Tools/Equipment Computer with CTC
Prerequisite procedures All shelf and card installation procedures
Required/As Needed Required
Onsite/Remote Onsite or remote
Table 7-2 E1, E3, and DS-3 Card Provisioning Overview (continued)
Provisioning Item E1-N-14 E3-12 DS3i-N-12
Table 7-3 E1-N-14 Card Parameters
Parameter Description Options
Line (Line tabs)
Port # Port number 1 - 14
Port Port name To enter a name for the port, click the
cell and type the name. To change a
name, double-click the cell, then edit
the text.