Cisco ONS 15454 SDH Installation and Operations Guide, R3.3
May 2002
Chapter 1 Hardware Installation
Installation Equipment
Caution Only use the power cable shipped with the ONS 15454 SDH.
1.2.2 User-Supplied Materials
The following materials and tools are required for installation but are not supplied with the ONS 15454
SDH.
Equipment rack (ETSI-rack, 2200 mm x 600 mm x 300 mm, H x W x D)
Fuse and alarm panel
Copper ground cable 13.3 mm² (#6 AWG) stranded, specified for up to 90° Celsius
Alarm cable pairs for all alarm connections, 0.51mm² or 0.64mm² (#22 or #24 AWG), solid-tinned
Single mode SC fiber jumpers with UPC polish (55 dB or better) for optical cards
Coaxial cable terminated with 1.0/2.3 miniature coax connectors for FMEC cards
DB-37 Connecting cable
Shielded BITS-clock coaxial cable terminated with 1.0/2.3 miniature coax connectors
Labels
1.2.2.1 Tools Needed
#2 Phillips screwdriver
Medium slot-headed screwdriver
Small slot-headed screwdriver
Video fiber connector inspection instrument
Cletop cleaning cassette
Crimping tool—This tool must be large enough to accommodate the girth of the grounding lug when
you crimp the grounding cable into the lug.
Wire stripping tool
1.2.2.2 Test Equipment
Volt meter
Power meter (only for use with fiber optics)
Bit Error Rate (BER) tester for E1-N-14, E3-12, DS3i-N-12, and FMEC cards