Chapter 5 SDH Topologies
Common Ring-Related Procedures
Figure 5-44 Enabling ports
Step 4 Click Apply.
Procedure: Check for Alarms
Step 1 Log into CTC on a network node and display the network view.
Step 2 Verify the following:
All spans on the network view are green.
On the Alarms tab (Figure 5-45 on page 5-62), no critical or major alarms are present, nor any
facility alarms, such as LOS or LOF. In a ring, these facility conditions may be reported as minor
alarms.
On the Conditions tab (Figure 5-46 on page 5-62), no ring switches are active.
If trouble is indicated, for example, a major alarm exists, resolve the problem before proceeding. Refer
to the Cisco ONS 15454 SDH Troubleshooting and Maintenance Guide for alarm troubleshooting
procedures.
Purpose This procedure explains how to check for alarms.
Onsite/Remote Onsite or remote
Line tab Provisioning tab
Status column
Card view Apply button