Cisco ONS 15454 SDH Installation and Operations Guide, R3.3
May 2002
Chapter 3 Node Setup
Setting Up ONS 15454 SDH Timing
Figure 3-12 Deleting a user from the node view
3.5 Setting Up ONS 15454 SDH Timing
SDH timing parameters must be set for each ONS 15454 SDH.
3.5.1 Timing Sources and Modes
Each ONS 15454 SDH independently accepts its timing reference from one of three sources:
The Timing A and Timing B connector on the MIC-C/T/P FMEC in Slot 24.
Note CTC refers to Timing A and Timing B as BITS (Building Integrated Timing Supply) 1 and BITS 2.
An STM-N card installed in the ONS 15454 SDH. The STM-N card is connected to a node that
receives timing through a BITS source.
The internal ST3 clock on the TCC-I card.
You can set ONS 15454 SDH timing to one of three modes: external, line, or mixed. If timing is coming
from the MIC-C/T/P FMEC timing connector, set ONS 15454 SDH timing to external. If the timing
comes from an STM-N card, set the timing to line.
Note The line timing mode is not available for 64 KHz.