Chapter 10 Alarm Monitoring and Management
Suppressing Alarms
Note Use alarm suppression with caution. If multiple CTC sessions are open, you will suppress the alarms
in all other open sessions.
Procedure: Suppressing Alarms
Step 1 At either the card view or node view, click the Provisioning > Alarm Behavior tabs.
At the card level, you can suppress alarms on a port-by-port basis. At the node level, you can suppress
alarms on a card-by-card basis or the entire node.
Step 2 Check the Suppress Alarms box for the card or port you want to suppress. Figure 10-13 shows the
Suppress Alarms box.
Figure 10-13 The suppress alarms checkbox
Step 3
Click the Apply button.
The node sends out autonomous messages to clear any raised alarms.
Purpose Suppressing alarms
Tools Computer, readily configured for CTC
Prerequisite procedures ONS 15454 SDH operational; CTC running
Required/optional Optional
Onsite/Remote Onsite or remote