Page view 353
9-8
Cisco ONS 15454 SDH Installation and Operations Guide, R3.3
May 2002
Chapter 9 Ethernet Operation
G1000-4 Card
Figure 9-5 Provisioning G1000-4 Ethernet ports
Step 3 If you want to label the port, double-click the Port Name heading. Click anywhere else on the screen to
save the change.
Step 4 Click the Enabled checkbox(s) to activate the corresponding Ethernet port(s).
Step 5 To disable/enable flow control negotiation, click the Flow Control Neg. checkbox.
Flow control negotiation is enabled by default.
Note Flow control is enabled only when the attached device is set for auto-negotiation. If
auto-negotiation has been provisioned on the attached device but the negotiation status indicates
no flow control, check the auto-negotiation settings on the attached device for interoperation
with the asymmetric flow control capability of the G1000-4.
Step 6 To permit the acceptance of jumbo size Ethernet frames, click the Max. Size column to reveal the
pull-down menu and select Jumbo.
The maximum accepted frame size is set to Jumbo by default.
Step 7 Click Apply.
Note Reprovisioning an Ethernet port on the G1000-4 card does not reset the Ethernet statistics for
that port. See the Statistics Window section on page 9-44 for information about clearing the
statistics for the G1000-4 port. Reprovisioning an Ethernet port on the E-series Ethernet cards
resets the Ethernet statistics for that port.