Cisco ONS 15454 SDH Specifications Page 292

  • Download
  • Add to my manuals
  • Print
  • Page
    / 504
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 291
7-14
Cisco ONS 15454 SDH Installation and Operations Guide, R3.3
May 2002
Chapter 7 Card Provisioning
Provisioning Electrical Cards
CVP Coding Violations Path Numeric. Defaults (DS3 Pbit, Near End
only; DS3 CPbit, Near and Far End):
25 (15 minutes)
250 (1 day)
ESP Errored seconds Path Numeric. Defaults (DS3 Pbit, Near End
only; DS3 CPbit, Near and Far End):
20 (15 minutes)
200 (1 day)
SESP Severely errored seconds Path Numeric. Defaults (DS3 Pbit, Near End
only; DS3 CPbit, Near and Far End):
3 (15 minutes)
7 (1 day)
SASP Severely errored frame/Alarm indication
signal Path
Numeric. Defaults (DS3 Pbit, Near End
only; DS3 CPbit, Near and Far End):
2 (15 minutes)
8 (1 day)
UASP Unavailable seconds Path Numeric. Defaults (DS3 Pbit, Near End
only; DS3 CPbit, Near and Far End):
10 (15 minutes)
10 (1 day)
SDH Thresholds (SDH Thrshld subtab)
Port # Port number 1 - 12
ES Errored seconds Numeric. Default (VC LO):
12 (15 minutes)
100 (1 day)
SES Severely errored seconds Numeric. Default (VC LO):
3 (15 minutes)
7 (1 day)
EB Errored blocks Numeric. Default (VC LO):
15 (15 minutes)
125 (1 day)
UAS Unavailable seconds Numeric. Default (VC LO):
10 (15 minutes)
10 (1 day)
BBE Background block error Numeric. Default (VC LO):
15 (15 minutes)
125 (1 day)
Table 7-5 DS3i-N-12 Card Parameters (continued)
Parameter Description Options